330 research outputs found

    Ultrasound IMT measurement on a multi-ethnic and multi-institutional database: Our review and experience using four fully automated and one semi-automated methods

    Get PDF
    Automated and high performance carotid intima-media thickness (IMT) measurement is gaining increasing importance in clinical practice to assess the cardiovascular risk of patients. In this paper, we compare four fully automated IMT measurement techniques (CALEX, CAMES, CARES and CAUDLES) and one semi-automated technique (FOAM). We present our experience using these algorithms, whose lumen-intima and media-adventitia border estimation use different methods that can be: (a) edge-based; (b) training-based; (c) feature-based; or (d) directional Edge-Flow based. Our database (DB) consisted of 665 images that represented a multi-ethnic group and was acquired using four OEM scanners. The performance evaluation protocol adopted error measures, reproducibility measures, and Figure of Merit (FoM). FOAM showed the best performance, with an IMT bias equal to 0.025 ± 0.225 mm, and a FoM equal to 96.6%. Among the four automated methods, CARES showed the best results with a bias of 0.032 ± 0.279 mm, and a FoM to 95.6%, which was statistically comparable to that of FOAM performance in terms of accuracy and reproducibility. This is the first time that completely automated and user-driven techniques have been compared on a multi-ethnic dataset, acquired using multiple original equipment manufacturer (OEM) machines with different gain settings, representing normal and pathologic case

    The efficacy of the new SCD Response Compression System in the prevention of venous stasis

    Get PDF
    AbstractObjective: The current commercially available sequential intermittent pneumatic compression device used for the prevention of deep venous thrombosis has a constant cycle of 11 seconds’ compression and 60 seconds’ deflation. This deflation period ensures that the veins are filled before the subsequent cycle begins. It has been suggested that in some positions (eg, semirecumbent or sitting) and with different patients (eg, those with venous reflux), refilling of the veins may occur much earlier than 60 seconds, and thus a more frequent cycle may be more effective in expelling blood proximally. The aim of the study was to test the effectiveness of a new sequential compression system (the SCD Response Compression System), which has the ability to detect the change in the venous volume and to respond by initiating the subsequent cycle when the veins are substantially full. Methods: In an open controlled trial at an academic vascular laboratory, the SCD Response Compression System was tested against the existing SCD Sequel Compression System in 12 healthy volunteers who were in supine, semirecumbent, and sitting positions. The refilling time sensed by the device was compared with that determined from recordings of femoral vein flow velocity by the use of duplex ultrasound scan. The total volume of blood expelled per hour during compression was compared with that produced by the existing SCD system in the same volunteers and positions. Results: The refilling time determined automatically by the SCD Response Compression System varied from 24 to 60 seconds in the subjects tested, demonstrating individual patient variation. The refilling time (mean ± SD) in the sitting position was 40.6 ± 10.0 seconds, which was significantly longer (P <.001) than that measured in the supine and semirecumbent positions, 33.8 ± 4.1 and 35.6 ± 4.9 seconds, respectively. There was a linear relationship between the duplex scan–derived refill time (mean of 6 readings per leg) and the SCD Response device–derived refill time (r = 0.85, P <.001). The total volume of blood (mean ± SD) expelled per hour by the existing SCD Sequel device in the supine, semirecumbent, and sitting positions was 2.23 ± 0.90 L/h, 2.47 ± 0.86 L/h, and 3.28 ± 1.24 L/h, respectively. The SCD Response device increased the volume expelled to 3.92 ± 1.60 L/h or a 76% increase (P =.001) in the supine position, to 3.93 ± 1.55 L/h or a 59% increase (P =.001) in the semirecumbent position, and to 3.97 ± 1.42 L/h or a 21% increase (P =.026) in the sitting position. Conclusions: By achieving more appropriately timed compression cycles over time, the new SCD Response System is effective in preventing venous stasis by means of a new method that improves on the clinically documented effectiveness of the existing SCD system. Further studies testing its potential for improved efficacy in preventing deep venous thrombosis are justified. (J Vasc Surg 2000;32:932-40.

    Extent of vascular plaque predicts future cardiovascular events in patients with systemic lupus erythematosus

    Get PDF
    OBJECTIVE: Patients with systemic lupus erythematosus (SLE) have increased prevalence of clinical cardiovascular disease (CVD) and subclinical atherosclerosis. Although 30-40% of patients with SLE have vascular plaque on ultrasound scanning, this study is the first to consider the relationship between total burden of plaque and subsequent CVD risk. METHODS: One hundred patients with SLE and without any previous clinical CVD underwent vascular ultrasound scans of both carotid and both common femoral bifurcations between 2011 and 2013. Clinical, serological, demographic and treatment data were collected at baseline. Patients were followed till 2020 to identify those who developed new onset coronary disease or stroke. Statistical analysis to identify factors associated with increased risk of developing CVD events was carried out. RESULTS: Thirty-six patients had plaque at baseline. During follow-up five patients (all had baseline plaque) developed coronary disease and two, without baseline plaque, developed lacunar strokes. Mean (SD) age of these patients was 46.5 (4.5) years. Patients with three or more baseline bifurcations with plaque were 10 times more likely to develop CVD than those with 0-2 bifurcations with plaques (OR 9.9, p= 0.009). TPA > 16mm2 was associated with six-fold increased risk of CVD (OR = 6.44, p= 0.028). Patients with disease duration > 14 years were more likely than those with disease duration < 14 years to develop CVD (OR 8.3 p= 0.043). CONCLUSIONS: The number of bifurcations with plaque and TPA in patients with SLE may be valuable in assessing risk of CVD and deciding on clinical measures to reduce this risk

    Hemispheric symptoms and carotid plaque echomorphology

    Get PDF
    AbstractPurpose: In patients with carotid bifurcation disease, the risk of stroke mainly depends on the severity of the stenosis, the presenting hemispheric symptom, and, as recently suggested, on plaque echodensity. We tested the hypothesis that asymptomatic carotid plaques and plaques of patients who present with different hemispheric symptoms are related to different plaque structure in terms of echodensity and the degree of stenosis. Methods: Two hundred sixty-four patients with 295 carotid bifurcation plaques (146 symptomatic, 149 asymptomatic) causing more than 50% stenosis were examined with duplex scanning. Thirty-six plaques were associated with amaurosis fugax (AF), 68 plaques were associated with transient ischemic attacks (TIAs), and 42 plaques were associated with stroke. B-mode images were digitized and normalized using linear scaling and two reference points, blood and adventitia. The gray scale median (GSM) of blood was set to 0, and the GSM of the adventitia was set to 190 (gray scale range, black = 0; white = 255). The GSM of the plaque in the normalized image was used as the objective measurement of echodensity. Results: The mean GSM and the mean degree of stenosis, with 95% confidence intervals, for plaques associated with hemispheric symptoms were 13.3 (10.6 to 16) and 80.5 (78.3 to 82.7), respectively; and for asymptomatic plaques, the mean GSM and the mean degree of stenosis were 30.5 (26.2 to 34.7) and 72.2 (69.8 to 74.5), respectively. Furthermore, in plaques related to AF, the mean GSM and the mean degree of stenosis were 7.4 (1.9 to 12.9) and 85.6 (82 to 89.2), respectively; in those related to TIA, the mean GSM and the mean degree of stenosis were 14.9 (11.2 to 18.6) and 79.3 (76.1 to 82.4), respectively; and in those related to stroke, the mean GSM and the mean degree of stenosis were 15.8 (10.2 to 21.3) and 78.1 (73.4 to 82.8), respectively. Conclusion: Plaques associated with hemispheric symptoms are more hypoechoic and more stenotic than those associated with no symptoms. Plaques associated with AF are more hypoechoic and more stenotic than those associated with TIA or stroke or those without symptoms. Plaques causing TIA and stroke have the same echodensity and the same degree of stenosis. These findings confirm previous suggestions that hypoechoic plaques are more likely to be symptomatic than hyperechoic ones. They support the hypothesis that the pathophysiologic mechanism for AF is different from that for TIA and stroke. (J Vasc Surg 2000;31:39-49.

    Screening for chronic cerebrospinal venous insufficiency (CCSVI) using ultrasound. Recommendations for a protocol

    Get PDF
    Chronic cerebrospinal venous insufficiency (CCSVI) is a syndrome characterized by stenoses or obstructions of the internal jugular and/or azygos veins with disturbed flow and formation of collateral venous channels. Ultrasound and venographic studies of the internal jugular and azygos venous systems in patients with multiple sclerosis (MS) have demonstrated a high prevalence of CCSVI (mean 71%, range 0-100%; n=1336)associated with activation of collaterals. By contrast, ultrasound and venographic examinations of normal controls and patients without MS have demonstrated a much lower prevalence (mean 7.1%, range 0-22%; n=505). Ultrasound in the form of duplex scanning uses a combination of physiological measurements as well as anatomical imaging and has been used for the detection of CCSVI by different centers with variable results. A high prevalence of obstructive lesions, ranging from 62% to 100%, has been found by some teams in patients with MS compared with a low prevalence (0-25%) in controls. However, others have reported absence of these lesions or a lower prevalence (16-52%). This variability could be the result of differences in technique, training, experience or criteria used. In order to ensure a high reproducibility of duplex scanning with comparable accuracy between centers a detailed protocol with standard methodology and criteria is needed. Also, standardization of the method of reporting of duplex measurements and other findings will facilitate validation of the proposed criteria by different centers. The aim of this document is to produce recommendations for such a protocol and indicate what future research is needed in order to address areas of uncertainty

    Ultrasonic plaque character and outcome after lower limb angioplasty

    Get PDF
    AbstractPurpose: The value of ultrasonic plaque characteristics in identifying patients at “high-risk” of restenosis after percutaneous transluminal angioplasty (PTA) was studied. Methods: Thirty-one arterial stenoses (6 common iliac, 2 external iliac, 1 profunda femoris, 21 superficial femoral, and 1 popliteal) in 17 patients who underwent angioplasty were studied by means of duplex scanning. With a computer-based program, B-mode images were digitized and normalized using 2 reference points, blood and adventitia. A grey level of 0 to 5 was allocated for the lumen (blood) and 180 to 190 for the adventitia on a linear gray scale of 0 to 255 (0 = absolutely black; 255 = absolutely white), and the overall plaque gray-scale median (GSM) of the pixels of the plaque was used as a measure of plaque echodensity. After PTA, follow-up of stenoses was done on day 1, weekly for 8 weeks, at 3 months, 6 months, and 1 year. The total plaque thickness (sum of anterior and posterior components), minimal luminal diameter (MLD), and peak systolic velocity ratio (PSVR) were measured for all stenoses. An increase of more than 2 in the PSVR was the duplex criterion used to signify restenosis. Results: The GSM of the stenoses before angioplasty ranged from 6 to 71 (mean, 31.3 ± 17.9); 17 stenoses had a GSM less than 25 (mean, 18.7 ± 5.3), and 14 had a GSM more than 25 (mean, 46.4 ± 15.8). When the GSM was less than 25, the absolute reduction in plaque thickness on day 1 post-PTA was 3.3 ± 1.8 mm, in contrast to 1.8 ± 1.6 mm when GSM was more than 25 (P < .03). The restenosis rate (PSVR more than 2) was 41% at 6 months and remained unchanged at 1 year. When the GSM was less than 25, restenosis occurred in 11% of lesions, in comparison with 78% when the GSM was more than 25 (P < .001). Conclusion: Plaque echodensity can be used to evaluate stenoses before PTA, to predict initial success and identify a subgroup that has a high prevalence of restenosis. The identification of a group at “high-risk” of restenosis can improve the selection of patients for the procedure and also be used in prospective studies on the prevention of restenosis. (J Vasc Surg 1999;29:110-21.

    Attention-Based UNet Deep Learning Model for Plaque Segmentation in Carotid Ultrasound for Stroke Risk Stratification: An Artificial Intelligence Paradigm

    Get PDF
    Stroke and cardiovascular diseases (CVD) significantly affect the world population. The early detection of such events may prevent the burden of death and costly surgery. Conventional methods are neither automated nor clinically accurate. Artificial Intelligence-based methods of automatically detecting and predicting the severity of CVD and stroke in their early stages are of prime importance. This study proposes an attention-channel-based UNet deep learning (DL) model that identifies the carotid plaques in the internal carotid artery (ICA) and common carotid artery (CCA) images. Our experiments consist of 970 ICA images from the UK, 379 CCA images from diabetic Japanese patients, and 300 CCA images from post-menopausal women from Hong Kong. We combined both CCA images to form an integrated database of 679 images. A rotation transformation technique was applied to 679 CCA images, doubling the database for the experiments. The cross-validation K5 (80% training: 20% testing) protocol was applied for accuracy determination. The results of the Attention-UNet model are benchmarked against UNet, UNet++, and UNet3P models. Visual plaque segmentation showed improvement in the Attention-UNet results compared to the other three models. The correlation coefficient (CC) value for Attention-UNet is 0.96, compared to 0.93, 0.96, and 0.92 for UNet, UNet++, and UNet3P models. Similarly, the AUC value for Attention-UNet is 0.97, compared to 0.964, 0.966, and 0.965 for other models. Conclusively, the Attention-UNet model is beneficial in segmenting very bright and fuzzy plaque images that are hard to diagnose using other methods. Further, we present a multi-ethnic, multi-center, racial bias-free study of stroke risk assessment
    • 

    corecore